Apps Lab Tips and Tricks: Estimating Transformer Parasitics Without an Impedance Analyzer
|
 |
Here's another situation where an engineer might need to estimate a value without the proper equipment to hand. This tip shows a practical way to estimate the value of the transformer primary winding stray capacitance and leakage inductance using an oscilloscope and current probe. As with estimating primary inductance, this method works well.